| PRSM-1 : Portable Radiation Survey Meter |
|
|
Portable Radiation Survey Monitor Model
PRSM-1 is a micro-controller based, portable battery operated instrument for measurement of environmental/ field dose rate
of Gamma and X-ray radiations. It is useful for Health Physics applications in Radioisotope Laboratories, Nuclear Power Plants, Nuclear Medical Centers. |
Specifications :
| Dose Rate Indicator | ||||||||
| Dose Rate Ranges | : | 0 - 200 mR/Hr (auto ranging) | ||||||
| Accuracy | : | ± 20% of Range | ||||||
| Energy Range | : | 100 KeV to 2 MeV | ||||||
| Integration Time (sec) | : |
|
||||||
|
High Voltage |
: |
0 to + 1000 Volts at 0.1 mA internally settable |
||||||
| Detector Probe | : | Halogen quenched
GM Tube Type 712 or equivalent Sensitivity : 18 CPS at 1 mR/Hr, Operating Voltage 500 - 900 Volts Housing : Size - 24 mm Dia x 110 mm Long, Aluminum tube Powder epoxy coated |
||||||
| Display | : | 16 x 2 line LCD for Dose Rate Indication | ||||||
| Backlit | : | User selectable ON or OFF | ||||||
| Chirper | : | Audio proportional to incident radiation rate. User selectable ON/OFF | ||||||
| General | ||||||||
| Dimensions | : | 140 W X 110 B X 50 H mm | ||||||
| Weight | : | Approximately 460 gms | ||||||
| Battery | : | 4 nos of 1.5 V Pencil Cells type AA (30 Hrs of operational life) or rechargeable NiCd Cells Optional | ||||||
| Accessories | ||||||||
|
Battery Charger |
: | 240V AC, 50 Hz mains operation | ||||||
|
|
|
| PRSM - A : Para Radiation Survey Monitor (GM Tube Based) |
|
|
|
Para Radiation Survey Monitor Model PRSM-A is a battery operated portable instrument designed for survey application in Nuclear Power Plants, Environmental Survey Labs. Etc. |
In Contamination Monitor mode, the analog display indicates Counts per sec. Typical ranges are 50, 500 and 5000 CPS. Dose Rate or Contamination Monitor modes are switch selectable.
PRSM-A, uses GM tube as radiation detector. GM Tube can be housed inside the instrument or can be supplied in an SS enclosure (with shutter arrangement for beta measurements) with suitable cable.
PRSM-A, works on a 9 V battery. Typical battery life is more than 15 hours if Alkaline battery is used. Battery charge level is indicated on the meter dial, for 3 seconds whenever the instrument is turned ON.
Specifications :
| Radiation Detected | : | Beta/Gamma (depending on the GM tube type used) |
| GM Detector | : | Internal or External with 1 meter long cable |
| Detector Housing | : | As required |
| Ranges | : | Dose Rate : 0 - 2, 20, 200 mR/Hr Contamination : 0 - 50, 500, 5000 CPS |
| Range Selection | : | x 1, x 10 , x 100 |
| Indication | : | Analog Meter Dial graduated in above ranges |
| Audio Output | : | Beep Rate proportional to dose rate (can be turned ON/OFF) |
| Battery Operation | : | 9 V Alkaline battery (Dura Cell or similar) |
| Battery Life | : | > 15 Hrs |
| Weight | : | Approximately 650 gms |
| Supplied with | : | Leather carrying case with shoulder strap & Instruction Manual |
| PCM-2 : Contamination Monitor |
|
|
|
PCM2, Contamination monitor is used for measurement of radioactive contamination in Nuclear Power Plants, Nuclear Medicine Centers. This instrument is ideally suitable for scanning material, tools, clothing, personnel etc. It is a mains operated unit & includes nuclear detector (GM tube) assembly probe and processing electronics. |
Specifications:
| Detector Assembly | ||
| Detector | : | Thin walled GM counter |
| Housing | : | Chrome plated brass tube with shield to prevent beta detection Size : 270 L x 32 D mm |
| HV supply | : | 0 to 1000 Volts @ 1 mA internally set at detector operating voltage |
| CRM and Failure Alarms | ||
| Alarms | : | Beeper and Red Flasher ON when count rate exceeds preset level |
| Set Point Adjustment | : | Adjustment over entire range. |
| Reset | : | Push switch to clear alarm condition |
| Failure Alarm | : | Red Flasher alarm is continuously ON if no pulse is detected within 60 secs |
| Count Rate Meter | ||
| Linear CRM | : | Three ranges of 0-10, 100 and 1000 CPS switch selectable |
| Accuracy | : | ±5 % of full scale |
| Display | : | Taut band 96 x 96 mm square panel meter, 270° deflection pointer movement |
| * (Other GM deyectors also can be offered as option) | ||
|
|
|
| PAG-3 : Para Area Gamma Monitor (GM Tube Based) |
|
|
|
Para Area Gamma Monitor Model PAG-3 is a micro-controller based; economical, stand-alone, mains operated instrument that uses GM tube as nuclear radiation detector. Necessary electronics & high voltage supply are housed in the equipment. PAG-3 has dose rate range 0 to 100 mR/Hr. Audio and visual alarms turn ON if the dose rate level exceeds the set value. Alarm relay change over contact is provided for external control or indication. This unit is supplied with an Auto ranging direct reading 3+1 digit 7 segment LED display for dose rate, preset alarm level and information related to instrument status, self test etc. |
PAG-3 is ideally useful for health physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc.
Alarm Level setting, Dose Rate calibration can be performed by using the two keys namely INC/DEC and MODE Key. Optional key lock feature restricts the editing only to the authorized personnel preventing the other persons from tampering the calibration or changing the Alarm
parameters.
Normal operating condition is indicated by illuminated large area Green LED. Red Flashing, large area LED accompanied by audio alarm indicates the dose rate alarm condition. On pressing the acknowledge key, the instrument will return to normal condition or may continue to flash alarm condition as the case may be. HV status is indicated by HV status indicator
LEDs.
Status Indication
Normal |
Steady Green LED |
Dose rate alarm |
Flashing Red LED & Audio Alarm |
On Acknowledge |
Steady Red LED if dose rate alarm level persists |
HV Normal |
Green LED ON |
HV fail |
“EHT FAIL “ message on3+1 digit 7 segment display |
No pulse / detector Fail |
“Tube FAIL “ message on 3+1 digit seven segment display. |
PAG-3 also performs self-diagnostics for HV failure, detector, counting, and memory electronics failure on power on.
Energy compensated GM tube or User specified GM tube also can be supplied with PAG-3.
Options
4 – 20 mA and/ or 0 to 5V full-scale output proportional to dose rate
RS232 - for Hand held configuration or PC COM port interface with data logging software.
RS485 – Multi drop serial Communication. The monitor will be able to send the instrument data like Instrument ID, dose rate, alarm level and Indication.
Specifications :
| Monitor | ||
| Design | : | Micro-controller based |
| Display | : | Auto ranging direct reading 3+1 digit 7 segment LED display For dose rate, Alarm level, status indication and self test |
| Range | : | 0.1 mR/Hr to 100 mR/Hr |
| Response time | : | Response time is
variable between 20 Secs to 1 Sec depending on dose rate |
| Accuracy | : | +/- 15 % through the range |
| Alarm range | : | 0.1 mR/Hr to 99.9 mR/Hr |
| Front panel Keys | : | 2 keys provided on front panel to set alarm level, Acknowledge and auto calibration |
| Indication | : | Large Area Green LED for Normal Indication. Large Area Red Flashing visual with audio alarm for dose rate Or Bright Red visual for No pulse alarm / detector fail alarm. HV fail LED / HV normal LED indication |
| Outputs | : | 2 Change Over potential free relay contacts |
| Construction | : | Wall mounting type |
| Dimension | : | 270 L x 120 D x 200 H mm |
| Options | : | 4 to 20 mA and or 0-5V Full Scale Output, RS-232 / RS-485 with data logging software |
| Detector ( GM Tube) | ||
| Detector | : | GM tube suitable for 0 to 100 mR/Hr range |
| Radiation detected | : | Gamma |
| Detector housing | : | Internally
mounted. External detector ( Optional) The GM detector probe will be located external to the monitor. It shall be housed in suitable, S.S/ Aluminum shell. Connecting cable between the detector and the monitor will be 10mtrs (typical) |
| Operating voltage | : | HV supply is factory set as per GM Tube specifications |
| * (Other GM deyectors also can be offered as option) |
||
|
|
Portal Monitor System offered by Para Electronics is intended to be used for detection unauthorized movement of nuclear material by personnel crossing the plant boundaries. The detection is based on Gamma Radiation emitted by nuclear material being carried by the personnel. Portal Monitor is designed for 24 hours continuous operation. Portal Monitor can be supplied with various types of detectors GM Tubes, Pan cakes, Plastic Scintillators or NaI(TI) detectors. Each type of detectors have certain advantages over other type with respect to detector efficiency, ruggedness, ease of operation and the cost. Adequate lead shielding can be provided for the detectors to improve minimum detectable activity. Settable response time, background subtraction facility, microcontroller based counting, Audio/Visual Flasher alarms are some of the standard features of Portal Monitors.
|
Number of detectors, mounting of detectors, lead shielding, type of detectors are configured according to the customers/users specifications. Typical configurations are 6 nos of NaI(Tl) detectors or 6 nos of Plastic Scintillators or 10-150 GM tubes with associated electronics for the basic structure of Para Portal Monitor.
Automatic occupancy detection, fast response time to detect the increase in counts over background counts, enables the user to set these parameters of his choice. Remote alarm indication and acknowledge are also provided for the Portal Monitor System.
Para Electronics can supply a modular system consisting of detectors, HV supplies, pulse processing unit and the counting system. Audio/Visual alarms, potential free relay contacts are provided for external alarm indication.
Portal Monitors can be supplied in different configurations. Para Electronics can supply any desired configuration as per user's requirements.
Typical Specifications :
| Number of Channels | : | 8 |
| Input for each Channel | : | TTL pulse of width 1 µsec or greater |
| Preset Time | : | 1 to 999 Seconds (software settable) |
| Alarm Counts for channel | : | 1 to 65000 (software settable) |
| Alarm Operating Logic | : | 1,2,3,4,5,6,7,8 out of 8 (software settable) |
| Maximum Counts per
Preset Time per Channel |
: | 65000 |
| Active Alarm Channel
Indicators |
: | LED indicators |
| Alarm level setting | : | a) Above Background Mode b) Absolute Counts Mode |
| Alarms | : | Red Flashing Visual Alarm Potential free Relay Contacts |
| Mechanical | ||
| Enclosure | : | Aluminum Powder Coated Frame |
| Dimensions | : | 310 L x 130 H x 220 W mm |
| Weight | : | Approximately 3 Kg |
| Power | : | 240 V (+ 10 %) AC, 50 Hz |
Laundry Monitor is developed for manual monitoring of beta/gamma contamination of clothing like lab-coats (aprons), boiler suits, hand gloves or shoe covers used by personnel in radioactive area in nuclear power plants/research labs. Normally these clothing are checked for contamination and segregated into active and non-active lots before sending out of the plant for processing by plant laundry. It is a practice to check inward laundry also to confirm whether the cloths are non-contaminated before use.
Para Electronics has supplied laundry Monitors of different configurations i.e. BOX type or FLAT BED type. Both these configurations use energy compensated GM Tubes. However beta/gamma sensitive tubes also can be supplied.
BOX Type Laundry Monitor
|
|
In BOX Type Laundry Monitor the system has Detector Head (measurement zone) adequate for type of laundry to be monitored. The measurement zone is covered by set of thin walled GM Tubes to measure beta/gamma radiations from the laundry. Relevant processing electronics is housed around the measurement zone. Suitable LED indicators are provided around the measurement zone to indicate zonal contamination level or hot spots of the laundry being monitored. Alarms and contamination level is indicated on contamination monitor (main measuring instrument) in CPS value in accordance to the user specifications. The size and shape of the measurement zone, contamination level ranges and background activity subtraction can be suitably modified to any different requirements. |
Specifications :
Detector Head
|
|
Flat Bed Type Laundry Monitor
|
|
|
FLAT BED type design employs 24 GM Tubes housed in 12 SS trays with lead lining. Each tray has HV supply and counting electronics for two tubes. The output from each tray is sent to the main counter unit which houses 12 independent counters. Background subtraction, No pulse Alarm, MIMIC Display and Audio/Visual Alarms are the standard features for Laundry Monitor. Automatic sensing of the laid cloth is detected by photo sensor and the counting is activated. MIMIC display gives indication of high contamination zones.
Specifications :
|
|
|
|
Scrap Monitor Model PSM-1 developed by Para Electronics is to cater the requirement of monitoring scrap for possible gamma contamination. This Monitor employs 6 nos. of energy compensated GM tubes. These thin walled GM tubes will be mounted parallel to the length of the Scrap Monitor. The housing of these GM tubes can be moved vertically for a span of nearly 700 mm. It’s lower most position will be at 40 mm from ground level and the highest position will be at 300 mm .The output of these GM Tubes will be OR tied and will be fed to Scrap Monitor’s display unit. This display unit consists of Count Rate Meter, Audio / Visual settable alarms, facility to subtract background level. Count Rate Metering circuit has 3 Ranges namely, 0 to 500 CPS, 0 to 5000 CPS and 0 to 50000 CPS. The alarm level can be set between 0 to 100% of any range. Analog Meter with 2700 square dial will indicate the CPS level. The integration time can be set to either 1 sec or 5seconds. Alarm levels are indicated on the same meter by setting the band switch to appropriate position. |
Contamination Monitor has a facility to subtract the background. It is possible to subtract the background upto 500 CPS. User can select background subtraction by setting background subtraction switch to ON position..
Typical Specifications :
|
Detector Head |
||
| Mechanical Dimensions | : |
Overall Dimensions
: 700 W x 500 H x 500 D mm (approx) Detector Housing with Stainless Steel Bottom : 700 W x 500 H x 100 D mm (approx) |
| Detector(s) used | : | Thin walled Halogen quenched GM Tubes with overall length 280 mm and diameter 28 mm |
| No of GM Tubes | : | 6 |
| HV Supply modules | : | One HV supply module per 3 GM tubes |
| No of HV modules | : | 2 |
| HV Output | : | Internally settable up to +900 V |
| Detector Head Output | : | OR tied TTL output from all the GM tubes will be fed to the contamination monitor. All outputs will be effectively averaged over the integration time 6 core cable 3 meter long |
|
Display Unit (Contamination Monitor) |
||
| Count Rate Ranges | : | 0 to 500 CPS, 0
to 5000 CPS, 0 to 50000 CPS Three switch selectable ranges |
| Input | : | TTL Input pulses from Detector Head |
| Alarm Level | : | Settable Alarm Level between 0 to 100% of selected range |
| Alarm Level Adjust | : | Single turn
potentiometer screw driver settable mounted on rear panel User can
set Alarm Level between 0 to 100% of selected range |
| Alarm Indication | : | Visual - RED
flashing LED indicator Audio – Audio Alarm External – Relay change over contact |
| Alarm Acknowledge | : | Front panel mounted push switch to reset the audio alarm. Visual alarm will switch off when the contamination level goes below the set value |
| Integration Time | : | 1 or 10 seconds switch selectable |
| CRM Indication | : | 100 mm x 100 mm square, 0 to 2700 Analog Meter |
| Background Subtraction | : | 0 to 500 CPS settable by 10 turn helipot with graduated dial |
| Mechanical | ||
|
Detector Head |
||
| Enclosure | : | Aluminum Powder Coated Box |
| Typical Dimensions | : | 807 W x 850 H x 400 D mm |
| Trolley | Steel Frame with adjustable vertical height for detector head | |
| Vertical Height Adjustment | From 40 mm to 300 mm by a bevel gear arrangement | |
| Contamination Monitor | ||
| Enclosure | Aluminum Powder Coated Box | |
| Dimensions | 310 W x 150H x 280 D mm | |
| Power | : | 240 V (+ 10 %) AC, 50 Hz Mains |
|
|
|
|
Trey Up Position |
Trey Down Position |
|
|
|
| PAM-1 : Plutonium in Air Monitor |
|
|
|
The increasing demand for safety of operators in nuclear plants, calls for continuous air monitoring. It is important to know beta and alpha activities remain below imposed limits. Plutonium In Air Monitor is useful to detect alpha particles in air due to low activity plutonium. The system will be useful at a place where fuel reprocessing / fabrication takes place. Important aspect of Plutonium In Air Monitor System is the charged particle detector. Silicon charged particle detectors such as diffused junction detector and surface barrier detector have served the scientific and industrial community for several decades. Modern ion implanted silicon detector such as PIPS detectors form the modern version of a charged particle detector. PIPS detectors have low leakage current and long-term stability which are desired features of continuous air monitors. |
Pu Monitor has a built in 1 K channel analyzer with input pulse range of 0 to 8 Volts. Each pulse from the spectroscopy amplifier is analyzed by the ADC and appropriately added to the spectrum. LCD graphics display provides the updated spectrum of counts verses channel continuously. As the input count rate is extremely low, there is no missing of any pulse as the conversion time of ADC is much faster (125 microsecond) than the input pulse rate.
The Pu Monitor has two operating modes – Setup Mode and Run Mode. Pu monitor has a facility to set up four ROIs, counting time interval and alarm level for each ROI integral. User can set two alarm levels. During run mode, ROI integral is calculated after completion of counting time interval. During fuel reprocessing, daughter products like radon are also generated. To cancel the effect of these products, user can set ROI for these products and can subtract the integral from ROI of Plutonium. If integral is above the first alarm level, visual alarm is activated. If integral is above the second alarm level, audio and visual alarms are activated. Second alarm level is for critical condition. Other features of the system include serial communication, relay outputs for remote monitoring.
Air sampling system is an integral part
of Plutonium in Air Monitor. For detection Silicon Surface Barrier or PIPS
detector with resolution of at least 20% is used. This detector is mounted
in detector housing. The filter holder assembly is fitted on the detector
housing. Vacuum pump sucks the air through the filter holder. Alpha
particles in the air deposit on the filter paper. The system is designed
in such a way that the filter paper can be replaced easily without
disturbing the detector. Trolley to place the vacuum pump, detector and
monitor unit can be provided. This arrangement makes the system portable.
Specifications :
Air Monitor Detection
Unit
Mains operated 1K MCA based unit
for the detection of Plutonium Alpha particles of energy 4.2 MeV to 5.5
MeV
| Detector | |
| Detector Type : | Ion Implanted Silicon Detector |
| Active Area : | 450 mm2 |
| Depletion Depth : | 100 microns |
| Resolution : | 21 KeV at 5.486 Mev |
| Pre Amplifier | |
| Type : | Low Noise Charge Sensitive Preamplifier |
| Gain : | 600 mV/pC |
| Rise Time : | Less than 100 nS |
| Fall Time : | 50 uS |
| Amplifier | |
| Input : | 0 to +500 mV |
| Output : | 0 to +8 Volts |
| Shaping : | 2 uS, Near Gaussian shape |
| Gain : | Overall 50, adjustable by potentiometer and high/low switch |
| HV | |
|
Range : |
0 to +100 V |
| Ramp-up Time : |
1 min/50V |
| ADC | |
| ADC Range : | 8 V |
| No of Channels : | 1024 |
| Time Interval : | 1 Sec to 999 Secs |
| Alarms | |
|
Flasher, buzzer and relay outputs (2 changeover) for alarm conditions |
|
| Others | |
| Temp. Range : | 0 to 55O C |
| RS232 Comm : | Possible |
| Air Sampling Unit | |
| Vacuum Pump : | Oil less, capacity 100 LPM with 12.7mm dia inlet and outlet ports |
| Rotameter : | Range 100 LPM |
| Filter Holder : | 25 mm Dia, SS construction |
(Suitable trolley will be provided with the system) |
|
|
|
|
| Teleprobe Surveyor |
|
Para Teleprobe Surveyor Model PTS-1 is a portable battery operated instrument for measuring radiation and for tracing gamma radioactive material or contamination. Two GM tubes contained at the end of telescopic probe serves as detectors. The dose rate is displayed on the analog meter with audio beep proportional to the input dose rate. Six 1.5V C type carbon cells in the handle of the instrument serve as power supply.
Wide measuring ranges from 0.1mR/H to 1000 R/h are switch selectable. Simple operation is provided by only one switch for all the functions of the instrument. An error-free reading, self-contained telescopic probe extendable upto 4 meters consequently increases safety factor from radiations source and facility for measurement in inaccessible places.
Typical Specifications :
| Radiation detected | : | Gamma |
| Detectors | : | Two GM tubes |
| Range | : | 0.1 mR/Hr to 1000 R/Hr |
| Range Switching | : | Power
Off 0-1000 R/h, 0-100 R/h, 0-10 R/h, 0-1 R/h 0-100 mR/h, 0-10 mR/h, 0-1 mR/h |
| Accuracy | : | + 15% through the range |
| Display** | : | Analog meter dial |
| Audio output | : | Beep rate proportional to the dose rate |
| Power | : | Six 1.5 'C' type carbon cells |
| Telescope Probe | : | 1.5
meter approx length when retracted and 4 meter Approx length when extended |
| (** Digital Indication can be provided instead of analog indication) | ||
|
|
Foot Monitor Model PFT-1 manufactured by Para Electronics is developed to detect the nuclear contamination on the shoes. This unit is designed around 4 nos of thin walled GM tubes (typ1 719) for detection of beta/gamma contamination on the bottom of the footware. A pulse from each GM tube is counted independently before all the counts are added together to determine if the aggregate counts are below the set level. Counting time, Alarm level are user settable. Audio/Visual alarms are provided when the contamination level crosses the set limit. LCD menu display indicates the status of the contamination and is used for diagnostic purposes also. The detection of person's standing is done by the pulses from GM tubes. GM tubes, 4 nos used in Model PFT-1 are surrounded by 6 mm thick lead shield. This reduces the background counts. Foot Monitor continuously counts the background counts and stores the latest background. These background counts are subtracted from the actual counts. Net counts are used fro alarm activation. |
Typical Specifications :
|
Detector Assembly |
||
| Detectors | : | 4 nos of
thin walled GM tubes type 719 or equivalent ( 2 GM tubes per foot) |
| Lead Shield | : | 6 mm thick lead shield on five sides around the GM tubes |
| S. S. Grill | ||