| PCM-3 : Portable Contamination Monitor, with Pancake Type GM Detector for Contamination Measurement |
|
|
Portable Contamination Monitor, Model PCM-3, is a micro controller based, portable ,light weight, battery operated instrument for measurement of environmental / field dose rate of gamma ray and x-ray radiation. It is useful for Health Physics applications in Nuclear Power Plants, Nuclear Medical Centers and Radio Isotope laboratories. Model PCM-3 employs external GM detector for direct readout of either dose rate in uR/hr, contamination in Bq/gm, Count Rate in CPS or CPM. With Pancake type GM tube, Model PCM-3 is useful for measurement of Contamination in Steel, other metals and alloys.
This pancake type GM tube is supplied externally with 1 meter
long cable. Portable Radiation Survey Monitor, Model PCM-3,
works on 6V rechargeable Ni-MH batteries. A mains operated
charger is also supplied with PCM-3 for keeping the batteries
charged. Typical operational battery charge life is 8 to 10
hours of continuous use. |
|
Selection of Material, either Aluminum or Iron or Cast Iron or Copper is provided. User can enter material thickness between 0.1 mm to 199.9 mm. Backlit ON/OFF key allows user to turn OFF the backlit to enhance the battery charge. Two line LCD display is used as interactive Menu for displaying Dose Rate in µR/Hr or Contamination in CPS or in Bq/gm and also to get the type of material and its thickness. Calibration of PCM-3 is done at factory, using Co-60 radioactive sources supplied by BRIT, Mumbai. A small check source (Co60) can be supplied as an option at extra cost. Dose Rate Alarm setting is also provided to activate an LED indicator when the incident dose rate value exceeds the set alarm value.
Model PCM-3 is supplied with
standard accessories like battery charger, operating manual and
carrying case. |
|
Specifications :
| Dose Rate Indicator | ||
| Measuring Ranges | : |
Contamination : 0.01 - 100.00 Bq / gm Dose Rate : 0 - 20,000 uR/Hr Count Rate : 0- 10,000 CPS |
| Detector | : | Pancake type, externally mounted with 1 meter long interconnecting cable |
| Radiation Detected | : | Alpha, Beta (without Shutter), Gamma/X Rays |
| Accuracy | : |
± 20% of Range
|
| Energy Range | : | 100 KeV to 2 MeV (Gamma) |
| Time Constant | : | 1 second for CPS and 10 second for Bq/gm or µR/Hr |
| Material | : | Aluminum, Copper, Iron and Cast Iron |
| Material Thickness | : | 0.1 to 200 mm |
| Menu Display | : | 16x 2 Characters LCD for display of reading and other parameters |
| Dose Rate Alarm | : | Settable in µR/Hr through out the range |
| Alarm Indication | : | Illuminated RED LED |
| Diagnostic Output | : | No pulse indication, Low battery indication |
| Audio Output | : | Chirper output proportional to incident dose rate |
| Backlit | : | User Selectable ON or OFF |
| Battery / Charger | : | 6 V Ni-MH battery with mains operated charger |
| Battery Life | : | More than 8 Hours per charging |
| Dimensions | : | 140 W x 110 B x 50 H centimeters |
| Weight | : | Approximately 500 gms |
| Standard Accessories | : | Operating Manual, Carrying Case |
| Check Source (Co60) | : | Optionally available at extra cost |
| Warranty | : | 1 year from date of dispatch |
| PRSM-1 : Portable Radiation Survey Meter |
|
|
Portable Radiation Survey Monitor Model
PRSM-1 is a micro-controller based, portable battery operated instrument for measurement of environmental/ field dose rate
of Gamma and X-ray radiations. It is useful for Health Physics applications in Radioisotope Laboratories, Nuclear Power Plants, Nuclear Medical Centers. |
Specifications :
| Dose Rate Indicator | ||||||||
| Dose Rate Ranges | : | 0 - 200 mR/Hr (auto ranging) | ||||||
| Accuracy | : | ± 20% of Range | ||||||
| Energy Range | : | 100 KeV to 2 MeV | ||||||
| Integration Time (sec) | : |
|
||||||
|
High Voltage |
: |
0 to + 1000 Volts at 0.1 mA internally settable |
||||||
| Detector Probe | : | Halogen quenched
GM Tube Type 712 or equivalent Sensitivity : 18 CPS at 1 mR/Hr, Operating Voltage 500 - 900 Volts Housing : Size - 24 mm Dia x 110 mm Long, Aluminum tube Powder epoxy coated |
||||||
| Display | : | 16 x 2 line LCD for Dose Rate Indication | ||||||
| Backlit | : | User selectable ON or OFF | ||||||
| Chirper | : | Audio proportional to incident radiation rate. User selectable ON/OFF | ||||||
| General | ||||||||
| Dimensions | : | 140 W X 110 B X 50 H mm | ||||||
| Weight | : | Approximately 460 gms | ||||||
| Battery | : | 4 nos of 1.5 V Pencil Cells type AA (30 Hrs of operational life) or rechargeable NiCd Cells Optional | ||||||
| Accessories | ||||||||
|
Battery Charger |
: | 240V AC, 50 Hz mains operation | ||||||
|
|
|
| PRSM - A : Para Radiation Survey Monitor (GM Tube Based) |
|
|
|
Para Radiation Survey Monitor Model PRSM-A is a battery operated portable instrument designed for survey application in Nuclear Power Plants, Environmental Survey Labs. Etc. |
PRSM-A, uses GM tube as radiation detector. GM Tube can be housed inside the instrument or can be supplied in an SS enclosure (with shutter arrangement for beta measurements) with suitable cable.
PRSM-A, works on a 9 V battery. Typical battery life is more than 15 hours if Alkaline battery is used. Battery charge level is indicated on the meter dial, for 3 seconds whenever the instrument is turned ON.
Specifications :
| Radiation Detected | : | Beta/Gamma (depending on the GM tube type used) |
| GM Detector | : | Internal or External with 1 meter long cable |
| Detector Housing | : | As required |
| Ranges | : | Dose Rate : 0 - 2, 20, 200 mR/Hr Contamination : 0 - 50, 500, 5000 CPS |
| Range Selection | : | x 1, x 10 , x 100 |
| Indication | : | Analog Meter Dial graduated in above ranges |
| Audio Output | : | Beep Rate proportional to dose rate (can be turned ON/OFF) |
| Battery Operation | : | 9 V Alkaline battery (Dura Cell or similar) |
| Battery Life | : | > 15 Hrs |
| Weight | : | Approximately 650 gms |
| Supplied with | : | Leather carrying case with shoulder strap & Instruction Manual |
| PCM-2 : Contamination Monitor |
|
|
|
PCM2, Contamination monitor is used for measurement of radioactive contamination in Nuclear Power Plants, Nuclear Medicine Centers. This instrument is ideally suitable for scanning material, tools, clothing, personnel etc. It is a mains operated unit & includes nuclear detector (GM tube) assembly probe and processing electronics. |
Specifications:
| Detector Assembly | ||
| Detector | : | Thin walled GM counter |
| Housing | : | Chrome plated brass tube with shield to prevent beta detection Size : 270 L x 32 D mm |
| HV supply | : | 0 to 1000 Volts @ 1 mA internally set at detector operating voltage |
| CRM and Failure Alarms | ||
| Alarms | : | Beeper and Red Flasher ON when count rate exceeds preset level |
| Set Point Adjustment | : | Adjustment over entire range. |
| Reset | : | Push switch to clear alarm condition |
| Failure Alarm | : | Red Flasher alarm is continuously ON if no pulse is detected within 60 secs |
| Count Rate Meter | ||
| Linear CRM | : | Three ranges of 0-10, 100 and 1000 CPS switch selectable |
| Accuracy | : | ±5 % of full scale |
| Display | : | Taut band 96 x 96 mm square panel meter, 270° deflection pointer movement |
| * (Other GM deyectors also can be offered as option) | ||
|
|
|
| PAG-3 : Para Area Gamma Monitor (GM Tube Based) |
|
|
|
Para Area Gamma Monitor Model PAG-3 is a micro-controller based; economical, stand-alone, mains operated instrument that uses GM tube as nuclear radiation detector. Necessary electronics & high voltage supply are housed in the equipment. PAG-3 has dose rate range 0 to 100 mR/Hr. Audio and visual alarms turn ON if the dose rate level exceeds the set value. Alarm relay change over contact is provided for external control or indication. This unit is supplied with an Auto ranging direct reading 3+1 digit 7 segment LED display for dose rate, preset alarm level and information related to instrument status, self test etc. |
PAG-3 is ideally useful for health physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc.
Alarm Level setting, Dose Rate calibration can be performed by using the two keys namely INC/DEC and MODE Key. Optional key lock feature restricts the editing only to the authorized personnel preventing the other persons from tampering the calibration or changing the Alarm
parameters.
Normal operating condition is indicated by illuminated large area Green LED. Red Flashing, large area LED accompanied by audio alarm indicates the dose rate alarm condition. On pressing the acknowledge key, the instrument will return to normal condition or may continue to flash alarm condition as the case may be. HV status is indicated by HV status indicator
LEDs.
Status Indication
Normal |
Steady Green LED |
Dose rate alarm |
Flashing Red LED & Audio Alarm |
On Acknowledge |
Steady Red LED if dose rate alarm level persists |
HV Normal |
Green LED ON |
HV fail |
“EHT FAIL “ message on3+1 digit 7 segment display |
No pulse / detector Fail |
“Tube FAIL “ message on 3+1 digit seven segment display. |
PAG-3 also performs self-diagnostics for HV failure, detector, counting, and memory electronics failure on power on.
Energy compensated GM tube or User specified GM tube also can be supplied with PAG-3.
Options
4 – 20 mA and/ or 0 to 5V full-scale output proportional to dose rate
RS232 - for Hand held configuration or PC COM port interface with data logging software.
RS485 – Multi drop serial Communication. The monitor will be able to send the instrument data like Instrument ID, dose rate, alarm level and Indication.
Specifications :
| Monitor | ||
| Design | : | Micro-controller based |
| Display | : | Auto ranging direct reading 3+1 digit 7 segment LED display For dose rate, Alarm level, status indication and self test |
| Range | : | 0.1 mR/Hr to 100 mR/Hr |
| Response time | : | Response time is
variable between 20 Secs to 1 Sec depending on dose rate |
| Accuracy | : | +/- 15 % through the range |
| Alarm range | : | 0.1 mR/Hr to 99.9 mR/Hr |
| Front panel Keys | : | 2 keys provided on front panel to set alarm level, Acknowledge and auto calibration |
| Indication | : | Large Area Green LED for Normal Indication. Large Area Red Flashing visual with audio alarm for dose rate Or Bright Red visual for No pulse alarm / detector fail alarm. HV fail LED / HV normal LED indication |
| Outputs | : | 2 Change Over potential free relay contacts |
| Construction | : | Wall mounting type |
| Dimension | : | 270 L x 120 D x 200 H mm |
| Options | : | 4 to 20 mA and or 0-5V Full Scale Output, RS-232 / RS-485 with data logging software |
| Detector ( GM Tube) | ||
| Detector | : | GM tube suitable for 0 to 100 mR/Hr range |
| Radiation detected | : | Gamma |
| Detector housing | : | Internally
mounted. External detector ( Optional) The GM detector probe will be located external to the monitor. It shall be housed in suitable, S.S/ Aluminum shell. Connecting cable between the detector and the monitor will be 10mtrs (typical) |
| Operating voltage | : | HV supply is factory set as per GM Tube specifications |
| * (Other GM deyectors also can be offered as option) |
||
|
|
Portal Monitor System offered by Para Electronics is intended to be used for detection unauthorized movement of nuclear material by personnel crossing the plant boundaries. The detection is based on Gamma Radiation emitted by nuclear material being carried by the personnel. Portal Monitor is designed for 24 hours continuous operation. Portal Monitor can be supplied with various types of detectors GM Tubes, Pan cakes, Plastic Scintillators or NaI(TI) detectors. Each type of detectors have certain advantages over other type with respect to detector efficiency, ruggedness, ease of operation and the cost. Adequate lead shielding can be provided for the detectors to improve minimum detectable activity. Settable response time, background subtraction facility, microcontroller based counting, Audio/Visual Flasher alarms are some of the standard features of Portal Monitors.
Number of detectors, mounting of
detectors, lead shielding, type of detectors are configured according to
the customers/users specifications. Typical configurations are 6 nos of
NaI(Tl) detectors or 6 nos of Plastic Scintillators or 10-150 GM tubes
with associated electronics for the basic structure of Para Portal
Monitor. |
Automatic occupancy detection, fast response time to detect the increase in counts over background counts, enables the user to set these parameters of his choice. Remote alarm indication and acknowledge are also provided for the Portal Monitor System.
Para Electronics can supply a modular system consisting of detectors, HV supplies, pulse processing unit and the counting system. Audio/Visual alarms, potential free relay contacts are provided for external alarm indication.
Portal Monitors can be supplied in different configurations. Para Electronics can supply any desired configuration as per user's requirements.
Typical Specifications :
| Number of Channels | : | 8 |
| Input for each Channel | : | TTL pulse of width 1 µsec or greater |
| Preset Time | : | 1 to 999 Seconds (software settable) |
| Alarm Counts for channel | : | 1 to 65000 (software settable) |
| Alarm Operating Logic | : | 1,2,3,4,5,6,7,8 out of 8 (software settable) |
| Maximum Counts per
Preset Time per Channel |
: | 65000 |
| Active Alarm Channel
Indicators |
: | LED indicators |
| Alarm level setting | : | a) Above Background Mode b) Absolute Counts Mode |
| Alarms | : | Red Flashing Visual Alarm Potential free Relay Contacts |
| Mechanical | ||
| Enclosure | : | Aluminum Powder Coated Frame |
| Dimensions | : | 310 L x 130 H x 220 W mm |
| Weight | : | Approximately 3 Kg |
| Power | : | 240 V (+ 10 %) AC, 50 Hz |
Laundry Monitor is developed for manual monitoring of beta/gamma contamination of clothing like lab-coats (aprons), boiler suits, hand gloves or shoe covers used by personnel in radioactive area in nuclear power plants/research labs. Normally these clothing are checked for contamination and segregated into active and non-active lots before sending out of the plant for processing by plant laundry. It is a practice to check inward laundry also to confirm whether the cloths are non-contaminated before use.
Para Electronics has supplied laundry Monitors of different configurations i.e. BOX type or FLAT BED type. Both these configurations use energy compensated GM Tubes. However beta/gamma sensitive tubes also can be supplied.
BOX Type Laundry Monitor
|
|
In BOX Type Laundry Monitor the system has Detector Head (measurement zone) adequate for type of laundry to be monitored. The measurement zone is covered by set of thin walled GM Tubes to measure beta/gamma radiations from the laundry. Relevant processing electronics is housed around the measurement zone. Suitable LED indicators are provided around the measurement zone to indicate zonal contamination level or hot spots of the laundry being monitored. Alarms and contamination level is indicated on contamination monitor (main measuring instrument) in CPS value in accordance to the user specifications. The size and shape of the measurement zone, contamination level ranges and background activity subtraction can be suitably modified to any different requirements. |
Specifications :
Detector Head
|
|
Flat Bed Type Laundry Monitor
|
|
|
FLAT BED type design employs 24 GM Tubes housed in 12 SS trays with lead lining. Each tray has HV supply and counting electronics for two tubes. The output from each tray is sent to the main counter unit which houses 12 independent counters. Background subtraction, No pulse Alarm, MIMIC Display and Audio/Visual Alarms are the standard features for Laundry Monitor. Automatic sensing of the laid cloth is detected by photo sensor and the counting is activated. MIMIC display gives indication of high contamination zones.
Specifications :
|
|
|
|
Scrap Monitor Model PSM-1 developed by Para Electronics is to cater the requirement of monitoring scrap for possible gamma contamination. This Monitor employs 6 nos. of energy compensated GM tubes. These thin walled GM tubes will be mounted parallel to the length of the Scrap Monitor. The housing of these GM tubes can be moved vertically for a span of nearly 700 mm. It’s lower most position will be at 40 mm from ground level and the highest position will be at 300 mm .The output of these GM Tubes will be OR tied and will be fed to Scrap Monitor’s display unit. This display unit consists of Count Rate Meter, Audio / Visual settable alarms, facility to subtract background level. Count Rate Metering circuit has 3 Ranges namely, 0 to 500 CPS, 0 to 5000 CPS and 0 to 50000 CPS. The alarm level can be set between 0 to 100% of any range. Analog Meter with 2700 square dial will indicate the CPS level. The integration time can be set to either 1 sec or 5seconds. Alarm levels are indicated on the same meter by setting the band switch to appropriate position. Contamination Monitor has a facility to subtract the background. It is possible to subtract the background upto 500 CPS. User can select background subtraction by setting background subtraction switch to ON position. |
Typical Specifications :
|
Detector Head |
||
| Mechanical Dimensions | : |
Overall Dimensions
: 700 W x 500 H x 500 D mm (approx) Detector Housing with Stainless Steel Bottom : 700 W x 500 H x 100 D mm (approx) |
| Detector(s) used | : | Thin walled Halogen quenched GM Tubes with overall length 280 mm and diameter 28 mm |
| No of GM Tubes | : | 6 |
| HV Supply modules | : | One HV supply module per 3 GM tubes |
| No of HV modules | : | 2 |
| HV Output | : | Internally settable up to +900 V |
| Detector Head Output | : | OR tied TTL output from all the GM tubes will be fed to the contamination monitor. All outputs will be effectively averaged over the integration time 6 core cable 3 meter long |
|
Display Unit (Contamination Monitor) |
||
| Count Rate Ranges | : | 0 to 500 CPS, 0
to 5000 CPS, 0 to 50000 CPS Three switch selectable ranges |
| Input | : | TTL Input pulses from Detector Head |
| Alarm Level | : | Settable Alarm Level between 0 to 100% of selected range |
| Alarm Level Adjust | : | Single turn
potentiometer screw driver settable mounted on rear panel User can
set Alarm Level between 0 to 100% of selected range |
| Alarm Indication | : | Visual - RED
flashing LED indicator Audio – Audio Alarm External – Relay change over contact |
| Alarm Acknowledge | : | Front panel mounted push switch to reset the audio alarm. Visual alarm will switch off when the contamination level goes below the set value |
| Integration Time | : | 1 or 10 seconds switch selectable |
| CRM Indication | : | 100 mm x 100 mm square, 0 to 2700 Analog Meter |
| Background Subtraction | : | 0 to 500 CPS settable by 10 turn helipot with graduated dial |
| Mechanical | ||
|
Detector Head |
||
| Enclosure | : | Aluminum Powder Coated Box |
| Typical Dimensions | : | 807 W x 850 H x 400 D mm |
| Trolley | Steel Frame with adjustable vertical height for detector head | |
| Vertical Height Adjustment | From 40 mm to 300 mm by a bevel gear arrangement | |
| Contamination Monitor | ||
| Enclosure | Aluminum Powder Coated Box | |
| Dimensions | 310 W x 150H x 280 D mm | |
| Power | : | 240 V (+ 10 %) AC, 50 Hz Mains |
|
|
|
|
Trey Up Position |
Trey Down Position |
|
|
|
| PTS-1 : Teleprobe Surveyor |
|
|
|
Para TeleSurveyer Model PTS-1 is a portable light-weight battery operated instrument for measuring radiation and for tracing gamma radioactive material or contamination. PTS-1 provides dose rate measurement in different units viz. CPS, R/Hr and mSv/Hr by front panel soft key. Wide measuring ranges from 1mR/Hr to 999.9 R/Hr or 1 µSv/Hr to 8640 mSv/Hr are auto-ranged. The response time is 2 to 50 secs inversely proportional to dose rate.
|
Typical Specifications :
| Radiation detected | : | Gamma |
| Range | Soft key
selectable AUTO-RANGING in units CPS, R/Hr or mSv/Hr 1 mR/Hr to 999.9 R/Hr, 1 µSv/Hr to 8640 mSv/Hr, 1 to 99999 CPS |
|
| Detectors | : | Energy
Compensated dual GM tubes with Auto switching Low Range 1mR/Hr to 800 mR/Hr 70003E by Vacutec or Equivalent High Range 600 mR/Hr to 999.9 R/Hr ZP1301 by Centronic or Equivalent Housed in a detachable Al cylindrical enclosure |
| Response | : | 2 to 50 secs inversely proportional to dose rate in AVG mode |
| Energy Response | ± 10 % for 100 KeV to 2 MeV | |
| Display | : | 64 X 128
pixel Graphic LCD Display with on demand BACKLIT Digital :- Large Font digital display with dose rate Units Analog :- 0 to 100 % bar graph with 2 % resolution Soft Keys :- UNIT, AVG, SPK Battery :- Normal/Low Iconic indication LR/HR :- Iconic display Low or High Range GM tube in use Alarms :- No Pulse, Battery Low and Probe Discontinuity Audio :- Beeps proportional to pulse rate Calibration facility with Soft Keys |
| Controls | : | Power ON/OFF , RESET, LCD Contrast, LCD Backlit ON |
| Power | : | Analog
4.5 Volt Rechargeable built-in Ni-Cd Battery pack 8 Hours continuous operation with backlit OFF External mains operated Battery Charger Unit provided |
| Mechanical | : | Measurement
and Display Unit of Elegant ABS Plastic - Size 85 W X 150 H X 30 D mm Black Telescopic detachable Probe Assembly - GM tubes Housing 30 mm dia X 175 mm long Cylindrical Aluminum Casing Telescopic Probe length - 830 mm fully Retracted - 1800 mm fully Extended |
| Weight | : | 1200 gms |
|
|
|
| PFT-1 : Foot Monitor |
|
|
|
Foot Monitor Model PFT-1 manufactured by Para Electronics is developed to detect the nuclear contamination on the shoes. This unit is designed around 4 nos of thin walled GM tubes (typ1 719) for detection of beta/gamma contamination on the bottom of the footware. A pulse from each GM tube is counted independently before all the counts are added together to determine if the aggregate counts are below the set level. Counting time, Alarm level are user settable. Audio/Visual alarms are provided when the contamination level crosses the set limit. LCD menu display indicates the status of the contamination and is used for diagnostic purposes also. The detection of person's standing is done by the pulses from GM tubes. GM tubes, 4 nos used in Model PFT-1 are surrounded by 6 mm thick lead shield. This reduces the background counts. Foot Monitor continuously counts the background counts and stores the latest background. These background counts are subtracted from the actual counts. Net counts are used fro alarm activation. |
Typical Specifications :
|
Detector Assembly |
||
| Detectors | : | 4 nos of
thin walled GM tubes type 719 or equivalent ( 2 GM tubes per foot) |
| Lead Shield | : | 6 mm thick lead shield on five sides around the GM tubes |
| S. S. Grill | : | On the top of the GM tubes |
| Light Switches | : | 2 nos to detect the standing of the person on the foot monitor |
|
Counter / Alarm Assembly |
||
| Electronics | : | Micro
controller based counter with 16x2 Line character LCD menu display for counts and other messages |
| No. of Channels | : | 2 with separate counters |
| Timer | : | Settable between 1 to 99 seconds |
| Alarms | : | Audio and Visual |
| Alarm Setting | : | Settable upto 9999 counts/measurement |
| Background Subtraction | : | Selectable ON or OFF |
| General | ||
| Dimensions | : | 460 L x 470 W x 150 H mm |
| Weight | : | Approximately 25 Kg |
| Power | : | 240 V (+ 10 %) AC, 50 Hz (Single Phase) |
|
|
|
| PAM-1 : Alpha Particulate Monitor |
|
|
|
Alpha Particulate Monitor Model PAM-1 developed by Para Electronicsconsists of following subsystems
Complete system is assembled on a trolley. System consists of a detector, preamplifier with filter paper holder. Detector is PIPS or surface barrier type. Preamplifier is directly mounted on the detector. Active area of the detector faces the filter paper. Filter paper is kept inside the filter paper holder. PIPS detectors or surface barrier detectors are sensitive to light. While changing the filter paper, it is necessary to switch off the bias for detector and the supply of the instrument. This step can be avoided by using a mylar layer on the detector. |
Preamplifier requires +12V and -12V
supply. Detector bias voltage is around 30 volts. Multicore cable with
one coaxial is used to carry the necessary voltage and the preamplifier
output between the preamplifier and the instrument. 6 pin allied
connector is used at the instrument end. Cable is directly soldered to
PCB at the preamplifier end.
Power supply for the instrument consists of +5V SMPS for digital
circuits. For +12 and -12V, linear supply is used. Inside the
instrument, there is a power supply card and the MCA card. Necessary
bias for the detector is generated on the power supply card.
Preamplifier output first goes to spectroscopy amplifier. Rise time of the amplifier output is 1.2 uS. Amplifier output is then given to 10 bit Wilkinson type ADC. Necessary signals for control of ADC are generated by the main controller C8051F340. This controller also handles the USB communication with the panel PC. Spectrum collected by 1K channel MCA is first stored in the internal memory of the PC. Then after every second, the spectrum is transferred to software package which runs on the panel PC. The spectrum collected by the MCA is displayed on the PC screen. Many other features like data storage are available in the package.
Mains supply is routed through the
spike guard. Vacuum pump is connected on the mains line whereas the
instrument and the panel PC are connected to the UPS as shown the block
diagram. UPS capacity is 500 VA. This gives backup time of at least 1
hour in case of power failure.
Vacuum pump capacity is 100 LPM. Normal suction rate through filter
paper is 40 LPM. This generates back pressure on the pump and results in
pump failure. Bypass valve is connected on the suction line of the pump
as shown in the diagram to avoid the back pressure on the vacuum pump.
Specifications :
Air Monitor Detection Unit
| 1K MCA based Unit for detection of Alpha particles | |
| Supply : | 230V, 50 Hz Mains |
| Radiation Detection : | 4.2 MeV to 8 MeV |
| System Resolution : | 300 KeV |
| Display : | In CPM and Bq/m3 |
| Pre Amplifier | |
| Detector Type : | Ion Implanted Silicon Detector |
| Resolution : | 20 KeV in Vacuum |
|
Active Area : |
450 mm2 |
|
Bias Voltage : |
+30 Volts |
| Pre Amplifier | |
| Type : | Low Noise Charge Sensitive Preamplifier |
| Output : | 100 mV for 5015MeV |
| Gain : | 600 mV/pC |
| Rise Time : | 2 uS |
| Fall Time : | 800 uS |
| Pulse Polarity : | Positive |
| Interconnecting cable length between preamplifier and amplifier - 3 meters | |
| Amplifier | |
| Input : | 0 to +500 mV |
| Output : | 0 to +8 Volts |
| Shaping : | 2 uS, Near Gaussian shape |
| Gain : | Variable through 10 turn helipot |
| HV | |
|
Range : |
0 to +100 V |
| Ramp-up Time : |
1 min/50V |
| ADC | |
| ADC Type : | 10 Bit Wilkinson Type |
| ADC Range : | 8 Volts |
| No. of Channels : | 1024Secs |
| Display & Storage System / Panel PC | |
|
Industrial Panel PC or Laptop with Windows XP (License version)
operating system for display of MCA spectrum, data analysis |
|
| ADC Range : | 8 Volts |
| No. of Channels : | 1024Secs |
| Alarms | |
|
Warning
Alarm Level & Final Alarm Levels settable in terms of Bq/m3.
Relay outputs 2 changeover for remote monitoring. |
|
| Flow Meter | |
|
Digital
Flow meter for flow rate measurement. |
|
| Others | |
| Temp. Range : | 0 to 55O C |
| Air Sampling Unit | |
|
SS Air Sampling head
capable of holding filter paper of 37 mm dia. Collection efficiency
>95%. Flow range 10 to 100 LPM Filter Paper Millipore type. Wire mesh for supporting filter paper. Vacuum Pump - Oil less, Capacity 100 LPM with 12.7mm dia inlet and outlet ports Digital Flowmeter, range 0 to 100LPM for flow rate measurement. Bypass valve for bypassing excess flow. Suitable Trolley will be provided for entire system with grills for ventilation. |
|