What
is
Static?
Electricity at rest.
How simple but inadequate this definition is of a natural phenomenon that
is most capricious. It costs industry millions of rupees every year!
It's manifestations are familiar to all of us. In the form of lightning and it's aftermath thunder, static strikes into old & young alike. For the brief
instant lightning flashes, static electricity is no longer at rest. There are
many examples encountered in industry which cannot be dismissed as
interesting, amusing or inevitable. Their effect can be to ignite, destroy, cause explosion or give fatal shock, create handling difficulties and spoil goods with dirt.
How can we control Static?
Basically there are two ways of controlling static:
PARA Electronics' Role
For over 20 years, PARA is manufacturing range of static measuring &
control instruments to fight the devil of static encountered in the industrial environment.
The instruments conform to the recommendations per IS7689-1989 of Bureau of Indian standards. In order to solve static problem, three basic steps must be taken:
-
Identify the problem :
The PARA Static Charge Meter will measure the amount and identify the polarity of static charge present. The meter will also help in checking effectiveness of ionisers /static eliminators.
-
Determine a Solution : Once the problem is identified, solution should be considered next. Can the static be controlled by grounding, ionization or a combination thereof. PARA offers air ionizing electrically powered static control equipment. This type of equipment is most effective in neutralizing static during manufacturing process.
-
Selecting proper equipment : Selection of a proper ioniser is most important. PARA offers a wide range of ionisers to suit every application. These ionisers are powered by an
electronically controlled HV power supply.
PARA's role is not, however, restricted to standard products. Possibility of using new designs as well as investigating problems is always under consideration.
|
|
| |
|
 |
| |
Measurement of Static Electricity |
|
| |
Static Charge Meter SCM-1
As the requirements for static protection and control have grown in recent years so has the need of
measurement equipment to monitor static charge. Location and measurement is the first step to control static. Static Charge Meter provides fast easy measurement of static charge, locates the source static charge and identifies the polarity.
SCM-1 is compact lightweight, battery-operated, non-contact type unit. It is easy to handle and enables quick detection and measurement of static potentials.
SCM-1 is certified intrinsically safe by Central Mining Research
Station, Dhanbad, for Group I, IIA & IIB hazardous areas.
|
 |
|
Range |
:
|
+/- 2.5 KV @ 2.5cm
+/- 5 KV @ 5.0 cm
|
|
Calibration Distance
|
:
|
2.5 cm
|
|
Accuracy
|
:
|
+/- 10%
|
|
Power
|
:
|
Two 9V Battries
|
|
Dimensions |
:
|
150L X 80W X 60H (mm) |
|
Weight
|
:
|
700gms |
(Supplied with a carrying case) Certified as "Intricically Safe"
|
|
|
| |
|
 |
| |
Elimination of Static Electricity |
|
| |
Ionisers effectively neutralize static charges of either polarity through ionisation of surrounding atmosphere. Ionisation
is achieved by AC high voltage corona discharge. Ions of either polarity
are generated. Different types of Ionisers can be connected to the control
unit. We offer range of Ioniser to suit customer needs.
Static Charge Controller
Static Charge Controller is a mains operated electronic control unit and generates AC high voltage supply to drive ionisers. Different types of ionisers can be connected to the control unit.
Static
Charge Eliminator SCE-1M
|
 |
High Voltage : 5KV to 10KV AC
Capacity : Can drive total of 4M length of Hot Bar and cable. The efficiency of elimination decreases as the length of the cable increases.
Facilities: Provision to connect three nos. PARA Ionisers. Air-inlet and three air- outlets for ionisers
requiring compressed air supply.
Safety Feature:
Auto reset electronic switch disconnects H.V supply to ioniser in the event of overload
due to :
1.
Operator inadvertently touching sharp needle points of the ioniser.
2. An unlikely event of ioniser short circuiting or ioniser H.V current
exceeding preset limit.
Power Requirement :
240V/120V, 50/60 Hz AC, 10VA max.
Mechanical Dimensions (in mm) :
150W X 150H X 210D
Weight :
5Kg. approx.
|
| |
|
Ioniser Selection
We Offer variety of Ioniser
as an accessory to SCE-1M for the effective elimination of the
static.
-
Bar Type
Ionisers - Hot Bar, Comb Bar
-
Small Volume Air Ionisers - Air Gun
Blower
-
Large Volume Air Ionisers - Ring
Ionisers
-
With Built-in Fans -
Laminar Flow Blower.
|
 |
Ring Ionisers : Designed
specifically to eliminate static produced in plastic pouches.
|
Pouch Size (cm) |
Inner Diameter (cm) |
Outer Diameter (cm) |
|
2.5 to 6 |
5, 7 or 9 |
17 |
|
8 to 12 |
11, 13 or 15 |
23 |
|
14 to 20 |
17, 19 or 21 |
29 |
|
|
 |
Laminar Flow Blower : A table top unit for static free
on-bench jobs. Semiconductor components, sensitive to static, can
be safely handled here
|
Effective distance :
|
In excess
of 1 meter |
|
Elimination of
efficiency : |
1 sec |
|
Power requirement :
|
240V/120V, 50/60 Hz AC,
60VA |
|
Size :
|
400W X 150H X 270D
mm |
|
Weight :
|
6 Kg |
|
|
 |
Hot Bar
Ioniser
Size :
30 mm x 30 mm x 1 mtr (Standard)
Effective distance : More than 25 mm
Elimination efficiency : 5 Secs
Application : Suitable for elimination of static on material in sheet
form in industries using or manufacturing rubber, bakelite,
Teflon coated rollers, processing rubber plastics etc.
|
|
|
Air Gun Blower
Effective distance : Upto 2.5 Mtr. Depending upon Air pressure
(max. 1 Kg / cm2)
Elimination efficiency : 0.8 Secs
Application : Bulk elimination in nonflammable or hazardous
environment. Hard to reach places like inside pipes, vessels,
fluidised air-bed dryers etc.
|
|
|
|
| |
|
 |
|
| |