PBI-1
: Broken Bag Indicator |
|
 |
Broken Bag Indicator, PBI-1 offered by Para Electronics, is
suitable for Fluidized Air Bed Dryers used in Pharma and Chemical
Industries.
PBI-1 works on tribo-electric principle. Current pulses generated
due to the impact of powder leak, are sensed by the probe unit
mounted in the exhaust duct .These input pulses are converted in
to 4 to 20 mA output. The Readout unit displays the current value
in % on a Bar Graph Display. 4 to 20 mA output and potential free
Alarm Relay Contacts are available for PLC operations. |
To avoid false alarms and to detect
genuine broken bag, time delayed alarm circuit is incorporated in the
readout unit. Delay time is adjustable between 7 to 70 seconds.
Self diagnostic current input signal is internally fed to the probe to
continuously monitor the reliable functioning of the Broken Bag
Indicator. The distance between the probe unit and readout unit can be
as long as 20 to 25 meters.
Specifications :
|
Read Out
Unit |
|
Input Current |
: |
4 to 20 mA as
received from Probe Unit |
|
Display Readout |
: |
Bar Graph
type Green color LED Indicating input current and set alarm level |
|
Preset Time |
: |
Settable
between 6~7 to 60~70 sec (approx) |
|
Alarm Output |
: |
LED
indication on front panel Change Over Relay Contacts |
|
POWER |
: |
240V AC Mains,
with proper earth |
|
Probe Unit |
| Input
Range |
: |
0 to 10 nA |
| Output
Range |
: |
4 to 20 mA |
|
Power Supply |
: |
± 12V DC
(Internally generated by Readout Unit) |
|
Connector |
: |
Allied type MS
3102R-14S-6P MIL Grade 6 Pin Male Connector |
|
Probe |
: |
SS, 10 mm dia x
250 mm long* Suitable for duct sizes of 200, 300, 400 mm dia |
|
Electronics |
: |
Aluminum
housing, 95 mm dia x 70 mm long |
|
Mounting |
|
1” dia Standard
NPT threads |
|
Mechanical |
|
Dimensions |
: |
150 L x 50 D x
100 H mm |
|
Weight |
: |
Approx 1 kg |
|
Interconnecting Cable |
: |
20 meter long |
| |
|
|
|
|
|
|
PVT-1
: Air Velocity Transmitter |
|
 |
Para Air Velocity Transmitter Model PVT-1 is designed for
measurement of air velocity in the duct for industrial
applications. It measures air velocity in range of 0 – 20 meters /
second. Model PVT-1 works on 24 V DC external supply and generates
4 to 20 mA output signal which is linearly proportional to air
velocity of 0 to 20 meters / sec. in the duct. This current output
can be transmitted through two wire signal cable to a distance
upto 100 meters with maximum termination resistor of 250 ohms in
the control panel, PLC or indicator unit for further processing.
Model PVT-1 sensor circuit is a robust, all solid state device
working on Kings law. Probe length suitable to the duct
diameter can be supplied. |
Specifications :
|
Air Velocity Range |
: |
0
to 20 meters/sec |
|
Output Range |
: |
4
to 20 mA |
|
Accuracy |
: |
±
5% of Full Scale |
|
Power Supply |
: |
+24V DC @ 200 mA (To be
supplied externally) |
|
Connector |
: |
3
pin Amphenol type |
|
Probe Construction |
: |
Stainless
Steel, 10 mm dia |
|
Probe Electronics |
: |
Aluminum
housing, 95 mm dia x 70 mm long |
|
Probe Mounting |
: |
3/4
Inch BSP threads |
|
Probe Rod Length |
: |
Suitable to duct diameter
and mounting arrangement.
(Dimensions to be specified by customer) |
| |
|
|
|
|
 |
|
PPASS-01
: Para Particle Aerodynamic Size Separator |
|
 |
Para Particle Aerodynamic Size Separator Model PPASS-01 is designed and developed for measurement of the size distribution in a host of applications such as pollution and atmospheric studies, inhalation hazard evaluation, characterizing lung delivery systems, material synthesis, etc.
PPASS-01 is based on the principle of inertial impaction and separates particles according to their aerodynamic diameters in the range of 0.53 to 10 m in seven class intervals. It has a special feature that it can be used with the number of stages less than the maximum of seven.
PPASS-01 is manufactured under license from Bhabha Atomic Research Centre, Mumbai. The design/technical knowhow transferred to Para Electronics- Manufacturing Division of Electronic Enterprises (India) Pvt. Ltd., is the product of developmental work by Environmental Assessment Division of BARC.
The PPASS-01 is useful for occupational monitoring of radioactive and non-radioactive environments, arising in the context of material processing, metal cutting, powder handling, etc. It is useful for air quality regulators as well as for researchers engaged in various aspects of air pollution and aerosol research. It can also be used by the pharmaceutical industries for characterising the lung aerosol delivery systems such as nebulisers and metered dose inhalers.
|
 |
Some important features of PPASS-01 are
- higher flow rate of 45 lpm, enabling a quicker collection of samples for analysis
- load any number of stages other than the maximum seven, depending upon the requirement
- new design of collection plates reduces inter-stage losses and ensures uniform particle deposits
- assembly or disassembly made easy by the use of stud and wing nut arrangement
- low internal wall losses
The adjoining graph shows the response functions for the impaction stages of PPASS-01 indicating the collection efficiency variation with particle size.
To standardize cut-off characteristics, a very simple and easy calibration method using well characterized, nebuliser generated polydisperse aerosols has been evolved. Each unit is tested for its stage response as per BARC test procedures.
|
Typical Stage :
|
A typical stage is shown alongside. Nozzle rings are made of aluminium alloy of grade 6061, collection and impaction plates are of stainless steel, connecting adapters and fasteners are of brass. The unit is made leakproof with the use of neoprene gaskets
|
|
Specifications :
|
Impactor Stages |
: |
7
Nos |
|
Operating Flow rate |
: |
45 lpm
|
|
Cut-off Diameters |
: |
8.95, 7.91, 6.09,4.15, 2.94, 1.03, 0.53
micro meter |
|
Collection Plate Holder |
: |
82 mm Dia |
|
Collection Substrate |
: |
70 mm Dia
|
|
Inlet Cone |
: |
25 mm dia |
|
Unit Dimensions |
: |
96 mm Dia x 230 mm Ht
|
|
Weight |
: |
2.5 Kg |
Accessories |
: |
1. Monoblock Dry Vacuum Pump 100 lpm with ¼ hp motor, 230V, 50Hz operation, 1440 rpm, 0-100 lpm Rotameter or Electronic Flow Transducer and Digital Indicatr, Flow Adjust Bleed Valve
2. Carrying Case for PPASS-01 and the pump |
| |
|
|
|
|
 |
|
PFI-1
: Para Air Flow Monitor |
|
 |
PARA AIR FLOW METER Model PFI - 100 Low and High level alarms can be set within the full range of air flow. Air flow totalizer is also provided to integrate air volume in Liters for the preset time. Model PFI-100 sensor circuit housed in the probe unit, is a robust, all solid state device working on Kings law. The length of interconnecting cable between probe unit and readout unit can be 3 meters long. Necessary ½” pipe couplings are provided to enable user install the probe in the air line.
Model PFI -100 is designed for measurement of air flow in the pipes for industrial applications. It measures air Flow in the range of 0 – 100 LPM. Model PFI-100 works on 240 V AC Mains Supply. It measures air flow in ½” dia pipe. This air flow is indicated on 4 x 20 char LCD Display. It also generates 4 to 20 mA output signal, linearly proportional to air flow in LPM. |
Specifications :
|
READOUT UNIT |
|
Air Flow Range |
: |
0
to 100 LPM |
|
Accuracy |
: |
±
5% of Full Scale |
|
Menu |
: |
4
x 20 Character LCD |
|
Keyboard |
: |
4 keys - TOT, SETUP,
ENTER, ESC |
|
Alarms |
: |
Low
and High Level |
|
Alarm Indication |
: |
LED
on front panel, Relay Contact |
|
Totalizer Time |
: |
Settable
up to 24:00 Hrs |
|
Totaliser On/
OFF |
: |
Through
Keypad |
|
Output |
: |
4 to 20 mA proportional
to LPM |
|
Operating Voltage |
: |
+240V
AC, 50 Hz Mains Supply |
|
Mechanical |
: |
Steel
Housing, panel mounting type |
|
Dimensions |
: |
140
W x 110 H x 210 D mm |
|
Output |
: |
4 to 20 mA proportional
to LPM |
|
PROBE UNIT |
|
Probe Construction |
: |
Stainless
Steel, M14, Threaded female port |
|
Dimensions |
: |
Stainless
Steel housing, 80 L x 70 H x 25 D mm |
|
Output |
: |
1~2 meters long, 3 core