Counting System |
|
||||
| Para Electronics offers offers different types of counting systems : | Radiation Monitor | ||||
| GM Counter | Alpha Counter | Portable Alpha Counter | RIA Counter | | NIM Modules | ||||
|
Alpha Counting system with Automatic Sample Changer |
Spectroscopy | ||||
| Data Acquisition | |||||
| PNC-1G : Para Nuclear Counter (GM Tube Based) |
|
|
Para Nuclear Counter Model PNC-1G is a
micro controller based, economical, stand alone, portable mains operated instrument for Nuclear Counting application. It is a versatile
instrument can be programmed as preset timer. |
Para Nuclear Counter Model PNC-1G can store 1000 readings in a non-volatile memory. These readings can be downloaded to PC via RS-232 interface or printed via parallel interface. These readings can also be scanned on LCD display after the counting experiment.
Model PNC-1G, is ideally suited for Nuclear Experiments carried out in Universities and colleges. It is also useful for radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, nuclear medicine centers etc.
End window GM tube Model 712 or equivalent can be supplied along with a planchet holder as an accessory for Model PNC-1G. Any other End Window GM tube can also be supplied as an option.
Lead Shield with door assembly is available as optional accessory for low level counting applications. It houses the GM Tube and planchet holder. Shield dimensions are development on the selected GM Tube.
Specifications :
| Electronics | : | All solid state, Micro-Controller based design. |
| Operating Modes | : | Preset Timer, CPS, CPM |
| Preset Timer | : | ON
Time settable between 1 to 9999 sec (* can be supplied in
HH:MM:SS format ) OFF Time settable between 1 to 9999 sec |
| Number of Runs | : | Settable between 1 to 1000 |
| Display | : | Counts : 999999 |
| Time : HH:MM:SS:CS | ||
| Runs : 1000 | ||
| HV Supply | : | Adjustable to 1000V by setting front panel mounted Helipot with calibrated dial |
| Data Storage | : | Store and recall facility for data up to 1000 readings |
| User Interface | : | 4 keys keypad with 16x2 line LCD for displaying Key function |
| Data Transfer | : | To PC
:RS232 COM Port To Printer : Centronics Parallel Port |
| Power | : | 240 V (+ 10%), 50 Hz Ac Mains |
|
Mechanical |
||
| Dimension | : | 200 L x 208 D x 90 H mm. |
| Weight | : | Approximately 1 kg |
|
Accessories |
||
|
GM Detector |
: | Model 712 make or as required |
|
Optional |
||
| Planchet Holder for End Window GM Tube | ||
| Lead Shield with door arrangement for GM tube and planchet holder | ||
| Aluminium Absorber Kit | ||
| Radioactive Sources (on request) | ||
|
|
|
| PNC-Alpha : Para Nuclear Counter (ZnS Tube Based) |
|
|
|
Para Alpha Counter Model PNC-Alpha is a micro-controller based, economical, stand alone, mains operated instrument for Alpha Counting application. Model PNC-Alpha, uses ZnS(Ag) alpha scintillator, is protected from stray light by a thin layer of aluminized myler sheet and is mounted on photo multiplier tube as nuclear radiation detector. Necessary electronics & high voltage supply are housed in the equipment. Coaxial cable with BNC connector connects the Alpha Detector to Model PNC-Alpha. Para Alpha Counter Model PNC-Alpha can store 1000 readings in a non-volatile memory. These readings can be downloaded to PC via RS-232 interface or printed via parallel interface. These readings can also be scanned on LCD display after the counting experiment. |
Model PNC-Alpha, is ideally suited for Nuclear Counting Experiments carried out in Universities and colleges. It is also useful for radiation counting for Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc.
Alpha Counter, in the standard form is supplied as a preset timer with 6 digit scaler. However, it is possible to supply it with modified software to include preset counts, CPS/CPM modes to suit to your requirement.
A Drawer Assembly to hold 1" dia or 2" dia filter paper is supplied as standard accessory. The detector mounts upside down on the drawer assembly such that myler face of the detector is just 2 mm above the sample filter paper.
Specifications:
| Electronics | : | All solid state, Micro-Controller based design. |
| Preset Timer | : | Time settable between 1 and 9999 seconds with Step of 1 second increment |
| Number of Runs | : | Settable between 1 and 1000 |
| Menu Display | Counts :
999999 Time : 9999 Runs : 1000 |
|
| HV Supply | : | Adjustable to 1000V by setting front panel mounted Trim pot |
| Data Storage | : | Store and recall facility for data up to 1000 readings |
| User Interface | : | 4 keys keypad with 16x2 line LCD for displaying Key function |
| Data Transfer | : | To PC : RS232 COM Port To Printer : Centronics Parallel Port |
| Power | : | 240V, 50 Hz AC Mains |
|
Mechanical |
||
| Dimension | : | 200 L x 208 D x 90 H mm. |
| Weight | : | Approximately 1 kg |
|
Detector |
||
| Alpha Probe | : | 2" dia ZnS(Ag) Scintillator with Mylar sheet, mounted on 2" dia PMT type B51D01 |
| Efficiency | : | Better than 25% |
| Background | : | Less than 10 Counts/Hr |
|
|
|
| ALSCIN : Para Alpha Scintillation Counter |
|
|
|
Para Alpha Scintillation Counter Model ALSCIN is a micro-controller based, economical, stand alone, battery as well as mains operated instrument for Alpha Counting applications.ALSCIN uses ZnS(Ag) alpha scintillator covered with aluminized myler, mounted on photo multiplier tube as nuclear radiation detector. Necessary electronics and high voltage supply are housed in the instrument. ALSCIN is useful for Alpha counting in Health Physics applications in radioisotope laboratories, nuclear reactors, nuclear power plants, environmental survey labs, etc. ALSCIN uses micro controller for counting, menu display and key board functions. Pulse processing electronics generates the TTL shaped pulses fed as input to the counter. Typical Alpha Counting efficiency is better than 25%. |
ALSCIN has 8x2 line LCD menu display with back-lit facility. Counts upto 999999 are displayed at the end of preset time. Timer can be set in Auto/Manual Mode. During Auto mode, ALSCIN counts the pulses for 1 minute time interval and then displays on LCD. In Manual mode of operation, Start/Stop key sets the start and end of counting time. Reset Key enables user to clear the counts taken in earlier run.
ALSCIN is supplied with a drawer assembly which enables user to keep 1" or 2" dia samples under the scintillator.
Specifications :
| Counter | ||
| User Interface | : | 8 Character LCD display for counts |
| Max. Counts | : | 999999 |
| Switches | : | Start/Stop/Reset Switches to control Manual mode |
| Preset Time | : | 1 minute (Auto Mode) or Manual |
| Indications | : | Low Batt indication |
| HV Supply | : | Settable between 100 to 1000V as required |
| Accessories | : | Calibration source holder for 1" dia source |
| Enclosure | : | Aluminum table top enclouser |
| Power | : | Battery Eliminator : 240V AC Mains input / 6V DC Output |
| Detector | ||
| Alpha Detector | : | Alpha Scintollation ZnS(Ag), integral assembly with voltage divider on 2" dia PMT |
| Viewing area | : | 20 cm2 approx, circular scintillator ZnS screen of 2" Dia on 2" Dia PMT |
| Detector Efficiency | : | Better than 25% |
| Drawer Assembly | : | 1" or 2" filter paper measurement |
| Mechanical | ||
| Dimensions (Overall) | : | 270 H x 140 W x 190 D mm |
| Weight | : | 3 Kg approx |
|
|
|
| PRIA-1 : PC Based Para RadioImmunoAssay Counter |
|
![]() |
Para Electronics offers PC based RIA counter Model PRIA-1 for measurement of in-vitro gamma radiations in nuclear medicine applications. PRIA-1, Para RadioImmunoAssay Counter is a micro-controller based, economical, mains operated instrument for measurement of in-vitro gamma radiations in nuclear medicine applications. Among the in-vitro applications of radioisotopes, RadioImmunoAssay has already been established as versatile and unique for variety of diagnostic procedures. PRIA –1 set up, consists of a detector and counting unit. The detector is a well type NaI(Tl) nuclear scintillation detector of size 1.5” dia x 2“ thick having a well of 0.75” dia x 1.5“ deep; optically coupled to a Photo Multiplier Tube sealed in a light tight package. It is surrounded by 15 mm thick lead to shield the detector from external/background radiations. The Read Out electronics is housed in an elegant ABS plastic enclosure. Coaxial cable with BNC connector connects the detector unit to the counting unit. This helps assembly, testing and maintenance of the instrument simple. |
Windows 98 or XP based data transfer and data reduction software
SAPRICAL is supplied with PRIA-1 (optional). Data transferred through RS-232 cable is processed by the data reduction facility
of SAPRICAL to carry out the calculations for standard assays and to plot the necessary graphs. It also stores the patients' data and finally generates the patient report.
PRIA-1, is also available as 'Two Channel RIA Counter' to perform
simultaneous counting of I-125 and Co-57 for measuring double labeled
assays such as Vitamin B-12 and Folate. Assisted by data reduction and
plotting software MAPRICAL. Simultaneous counting in both the channels
is achieved which saves the evaluation time.
PRIA-1, is a very useful diagnostic tool, needed in every small, medium or large-scale pathological laboratory for clinical evaluation of the vitally important biological ingredients such as hormones, vitamins and steroids for early diagnosis of various diseases.
For dual channel RIA counter PRIA-1 (set for two channel) with MAPRICAL software will be offered.
Specifications :
| Detector with Lead Shield | ||||||
| Detector Type | :
Well type NaI(Tl) crystal of size 1.5” dia coupled high counting
Efficiency (greater than 70%) |
|||||
| Operating Voltage | : 800-1000 Volts (as per detector specifications) | |||||
| Well Size | : 0.75” dia x 1.5” deep | |||||
| Background | : Less than 60 CPM for I-125 | |||||
| Well Liner | : Removable plastic well liner to prevent detector contamination | |||||
| Read Out Unit | ||||||
| Analyzer | : Single Channel Analyzer set for I-125 | |||||
| Keyboard | : Local 4 keys keypad to set counting time | |||||
| Display | : 16x2 line LCD display for diagnostic purpose | |||||
| Counting Time | : In steps of 10, 30, 60, 100, 200, 400, 800, 1000 Seconds | |||||
| Mechanical |
Dimensions |
Weight |
||||
|
Detector (With Lead Shield) |
170 Φ(Base) x 255 H mm |
5 Kg (Approx.) |
||||
|
Read Out Unit |
200 L x 228 D x 90 H mm |
1 Kg (Approx.) |
||||
| Electrical | ||||||
|
Power |
: 240V (±10%) AC, 50Hz or 4 nos. Dry Cells type C | |||||
| Data Reduction 'SAPRICAL' Software | ||||||
|
||||||
|
|
|
| PACASC : PC Based Para RadioImmunoAssay Counter |
|
|
|
Para Alpha Counting System Model PACASC is Industrial PC based
stand alone mains operated system for Alpha radiation counting
on disc type filter paper samples or planchets of 38mm dia.
Model PACASC is with automatic sample changer to count samples
up to 10 nos in each run. Model PACASC is with Menu based touch
screen for ease of unattended operation for pre-programmed
sample positioning, counting and report generation. |
Specifications :
| Radiations detected | : | Alpha radiations from disc type filter papers/planchets | |||||||||||||||||||
| Detector | : | 51mm dia ZnS(Ag) Scintillator mounted on 51mm dia PMT | |||||||||||||||||||
| Efficiency | : | better than 25% | |||||||||||||||||||
| Background | : | less than 3-4 counts/Hour | |||||||||||||||||||
| Alpha Counts capacity | : | 0 to 999999 counts | |||||||||||||||||||
| Sample size | : | 38mm dia disc type filter paper or planchet | |||||||||||||||||||
| No.of Samples / RUN | : | 10 nos. | |||||||||||||||||||
| Sample Counting time | : | Settable between 0 to 9999 seconds in steps of 1 sec | |||||||||||||||||||
| Next Sample travel time | : | 5 secs | |||||||||||||||||||
| Sample Elevation time | : | 10 secs | |||||||||||||||||||
|
System Operating Modes |
|||||||||||||||||||||
SETUP
mode to set system operating parameters as follows:
|
|||||||||||||||||||||
| SCA
operation in Threshold or Window mode is hardware jumper
selectable. Note : Spectroscopy amplifier with 2 usec shaping time is built in with adjustable gain suitable for the detector. |
|||||||||||||||||||||
|
RUN mode
to operate the system with set parameters :
|
|||||||||||||||||||||
| Start | : | Start Alpha Counting samples in set sequence | |||||||||||||||||||
| Stop | : | Aborts present counting and brings the sample to rest position. | |||||||||||||||||||
| REPORT mode to generate reports after completion of counting process : : | |||||||||||||||||||||
| Sample ID, Counts, date, time, system parameters etc in predefined formats are saved and available for printing on USB port. | |||||||||||||||||||||
|
General |
|||||||||||||||||||||
| Power | : | 230 V (+/- 10 %), 50 Hz Mains | |||||||||||||||||||
| Mechanical Dimension | : | 270L x160 W x 320D mm | |||||||||||||||||||
| Weight | : | Approx 15 kg | |||||||||||||||||||
Copyright © 2007 Para Electronics, Manufacturing Division of Electronic Enterprises (I) Pvt. Ltd.